one360 Engineering
EN

ONE360 · POOL HEATING

Pool heat pumps in Spain

A pool heat pump matched to your climate, cover and target temperature. Start with the pool dimensions and when you want to swim.

Find my pool heating
01

A heat pump for the pool

Purpose-built equipment heats pool water through a dedicated heat exchanger. We check filtration flow, location and electrical supply.

02

Cover and heat loss

Water surface area, wind, night temperatures and the cover affect heat loss. The same volume does not mean the same required output.

03

Your swimming season

Summer evenings, spring and autumn or year-round use need different design conditions. Water temperature and usage matter too.

Compare under the same conditions

Output and COP change with air and water temperature. Peak COP usually occurs at part load and does not coincide with maximum heat output.

Example: Eco Elyo-13 provides up to 13 kW at 26 °C air, 26 °C water and 80% humidity; up to 9 kW at 15 °C air, 26 °C water and 70% humidity.

Official performance source

Equipment for an initial comparison

These are real pool-specific models. Listing one does not confirm that it is correctly sized. Heat losses and installation need checking first.

AstralPool Eco Elyo-09

Official Eco Elyo series image.

AstralPool Eco Elyo-09

Pool heat pump · Full Inverter · recommended water flow 4 m³/h · 220–240 V, single-phase.

Air 26 °C · Water 26 °C · Humidity 80%

Heating output: 9.5 kW

COP: 6.7–13.5

Maximum heat output. COP covers the speed range; peak COP is not simultaneous with maximum output.

Air 15 °C · Water 26 °C · Humidity 70%

Heating output: 7 kW

COP: 5.3–6.6

Maximum heat output. COP covers the speed range; peak COP is not simultaneous with maximum output.

Catalogue includes a cover, condensate drain kit, 2 PVC Ø50 unions and 4 anti-vibration supports. Bypass, pipework, electrical supply, installation and commissioning need separate checks.

Price to confirmManufacturer details
AstralPool Eco Elyo-13

Official Eco Elyo series image.

AstralPool Eco Elyo-13

Pool heat pump · Full Inverter · recommended water flow 5 m³/h · 220–240 V, single-phase.

Air 26 °C · Water 26 °C · Humidity 80%

Heating output: 13 kW

COP: 6.5–16.4

Maximum heat output. COP covers the speed range; peak COP is not simultaneous with maximum output.

Air 15 °C · Water 26 °C · Humidity 70%

Heating output: 9 kW

COP: 4.8–7.8

Maximum heat output. COP covers the speed range; peak COP is not simultaneous with maximum output.

Catalogue includes a cover, condensate drain kit, 2 PVC Ø50 unions and 4 anti-vibration supports. Bypass, pipework, electrical supply, installation and commissioning need separate checks.

Price to confirmManufacturer details
AstralPool Eco Elyo-20T

Official Eco Elyo series image.

AstralPool Eco Elyo-20T

Pool heat pump · Full Inverter · recommended water flow 7 m³/h · 380–400 V, three-phase.

Air 26 °C · Water 26 °C · Humidity 80%

Heating output: 20 kW

COP: 5.5–12.3

Maximum heat output. COP covers the speed range; peak COP is not simultaneous with maximum output.

Air 15 °C · Water 26 °C · Humidity 70%

Heating output: 14.8 kW

COP: 4.6–7.5

Maximum heat output. COP covers the speed range; peak COP is not simultaneous with maximum output.

Catalogue includes a cover, condensate drain kit, 2 PVC Ø50 unions and 4 anti-vibration supports. Bypass, pipework, electrical supply, installation and commissioning need separate checks.

Price to confirmManufacturer details
Zodiac Z550iQ MD4

Official Z550iQ MD4 image.

Zodiac Z550iQ MD4

Pool heat pump · Full Inverter · vertical air discharge · 220–240 V, single-phase.

Air 28 °C · Water 28 °C · Humidity 80%

Heating output: 12.5 kW

COP: 6.3–12

Maximum heat output. COP covers the speed range; peak COP is not simultaneous with maximum output.

Air 15 °C · Water 26 °C · Humidity 70%

Heating output: 9.5 kW

COP: 5–6.7

Maximum heat output. COP covers the speed range; peak COP is not simultaneous with maximum output.

R32-version data from the 2025 manual. Price and configuration need confirmation: reviewed seller offers mix old and current versions. Published operating water temperature: 10–32 °C.

Price to confirmManufacturer details
Klinwass Mini 2.75 kW

Klinwass Mini 2.75 kW

Pool heat pump · electrical supply: 220–240 V · refrigerant: R32.

Selection requires a thermal assessment and checks of flow, electrical supply and the manual of the supplied unit. The public retail price is equipment only; delivery and additional work are confirmed separately. The listing is Mini 2.75 kW, but its linked sheet describes Mini 3 kW and differs in output, COP, dimensions and weight. Those performance figures are not assigned to this item without confirming the exact unit.

Price to confirmProduct source
Kripsol i-Komfort RC 700

Kripsol i-Komfort RC 700

Pool heat pump · electrical supply: 220–240 V / 50 Hz · single-phase · refrigerant: R32. Published indicative pool volume: ≤ 25 m³. Private covered pool, May to September and ambient air at least 15 °C; the sheet states additional usage conditions.

Air 27 °C · Water 26 °C · Humidity 78%

Mode: Maximum

Heating output: 7.33 kW

COP: 6.3

Maximum output; peak COP over the modulation range is not simultaneous with this output.

Air 27 °C · Water 26 °C · Humidity 78%

Mode: Mid-load

Heating output: 5.5 kW

COP: 8.02

Mid-load according to the datasheet; not maximum output.

Air 15 °C · Water 26 °C · Humidity 71%

Mode: Maximum

Heating output: 5.36 kW

COP: 4.69

Maximum output; peak COP over the modulation range is not simultaneous with this output.

Air 15 °C · Water 26 °C · Humidity 71%

Mode: Mid-load

Heating output: 3.72 kW

COP: 5.23

Mid-load according to the datasheet; not maximum output.

Selection requires a thermal assessment and checks of flow, electrical supply and the manual of the supplied unit. The public retail price is equipment only; delivery and additional work are confirmed separately. The retailer advertises 30 m³; its linked RC700 sheet specifies a maximum of 25 m³. The newer RC700A is not substituted.

Price to confirmProduct source
AstralPool ECO ELYO-07

AstralPool ECO ELYO-07

Pool heat pump · electrical supply: 220–240 V / 50–60 Hz · single-phase · refrigerant: R32.

Air 26 °C · Water 26 °C · Humidity 80%

Mode: Maximum

Heating output: 7 kW

COP: 6.5

Maximum output; peak COP over the modulation range is not simultaneous with this output.

Air 15 °C · Water 26 °C · Humidity 70%

Mode: Maximum

Heating output: 5.5 kW

COP: 5.2

Maximum output; peak COP over the modulation range is not simultaneous with this output.

Selection requires a thermal assessment and checks of flow, electrical supply and the manual of the supplied unit. The public retail price is equipment only; delivery and additional work are confirmed separately. The retailer title’s 30 m² is an area, not a water volume. It is not converted to m³.

Price to confirmProduct source
Midea MSC-90D2N8-A

Midea MSC-90D2N8-A

Pool heat pump · electrical supply: 220–240 V / 50 Hz · single-phase · refrigerant: R32. Published indicative pool volume: < 45 m³ · A15/W28. Published indicative volume does not specify cover, wind or operating schedule; it does not guarantee performance.

Air 27 °C · Water 28 °C · Humidity 80%

Mode: Nominal

Heating output: 9.15 kW

COP: 6.8

Nominal mode; separate from Boost.

Air 27 °C · Water 28 °C · Humidity 80%

Mode: Boost

Heating output: 12.8 kW

COP: 6

Boost mode at the stated conditions.

Air 15 °C · Water 28 °C · Humidity 70%

Mode: Nominal

Heating output: 6.8 kW

COP: 4.9

Nominal mode; separate from Boost.

Air 15 °C · Water 28 °C · Humidity 70%

Mode: Boost

Heating output: 9.3 kW

COP: 4.45

Boost mode at the stated conditions.

Selection requires a thermal assessment and checks of flow, electrical supply and the manual of the supplied unit. The public retail price is equipment only; delivery and additional work are confirmed separately. Water limits differ between Midea sheet revisions. Confirm them in the supplied manual; operation at −7 °C does not establish available heating output at that temperature.

Price to confirmProduct source
Midea MSC-160D2N8-A

Midea MSC-160D2N8-A

Pool heat pump · electrical supply: 220–240 V / 50 Hz · single-phase · refrigerant: R32. Published indicative pool volume: < 80 m³ · A15/W28. Published indicative volume does not specify cover, wind or operating schedule; it does not guarantee performance.

Air 27 °C · Water 28 °C · Humidity 80%

Mode: Nominal

Heating output: 16 kW

COP: 6

Nominal mode; separate from Boost.

Air 27 °C · Water 28 °C · Humidity 80%

Mode: Boost

Heating output: 18.7 kW

COP: 5.1

Boost mode at the stated conditions.

Air 15 °C · Water 28 °C · Humidity 70%

Mode: Nominal

Heating output: 12.8 kW

COP: 4.5

Nominal mode; separate from Boost.

Air 15 °C · Water 28 °C · Humidity 70%

Mode: Boost

Heating output: 15 kW

COP: 3.8

Boost mode at the stated conditions.

Selection requires a thermal assessment and checks of flow, electrical supply and the manual of the supplied unit. The public retail price is equipment only; delivery and additional work are confirmed separately. Water limits differ between Midea sheet revisions. Confirm them in the supplied manual; operation at −7 °C does not establish available heating output at that temperature.

Price to confirmProduct source
Midea MSC-200D2N8-A

Midea MSC-200D2N8-A

Pool heat pump · electrical supply: 220–240 V / 50 Hz · single-phase · refrigerant: R32. Published indicative pool volume: < 100 m³ · A15/W28. Published indicative volume does not specify cover, wind or operating schedule; it does not guarantee performance.

Air 27 °C · Water 28 °C · Humidity 80%

Mode: Nominal

Heating output: 18.8 kW

COP: 5.2

Nominal mode; separate from Boost.

Air 27 °C · Water 28 °C · Humidity 80%

Mode: Boost

Heating output: 21.8 kW

COP: 4.4

Boost mode at the stated conditions.

Air 15 °C · Water 28 °C · Humidity 70%

Mode: Nominal

Heating output: 14.5 kW

COP: 4.2

Nominal mode; separate from Boost.

Air 15 °C · Water 28 °C · Humidity 70%

Mode: Boost

Heating output: 17 kW

COP: 3.6

Boost mode at the stated conditions.

Selection requires a thermal assessment and checks of flow, electrical supply and the manual of the supplied unit. The public retail price is equipment only; delivery and additional work are confirmed separately. Water limits differ between Midea sheet revisions. Confirm them in the supplied manual; operation at −7 °C does not establish available heating output at that temperature.

Price to confirmProduct source
Klinwass Dolphin 5.5 kW

Klinwass Dolphin 5.5 kW

Pool heat pump · electrical supply: 220–240 V / 50 Hz · single-phase · refrigerant: R32.

Air 27 °C · Water 26 °C · Air wet bulb 24.3 °C · Outlet water 28 °C

Mode: Boost

Heating output: 5.5 kW

COP: 6.55

Boost mode at the stated conditions. Inlet water 26 °C and outlet 28 °C; air wet bulb 24.3 °C.

Air 15 °C · Water 26 °C · Air wet bulb 12 °C

Mode: Boost

Heating output: 3.9 kW

COP: 5.2

Boost mode at the stated conditions. Inlet water temperature; air wet bulb 12 °C.

Selection requires a thermal assessment and checks of flow, electrical supply and the manual of the supplied unit. The public retail price is equipment only; delivery and additional work are confirmed separately. The listing and technical documents, or document revisions, contain conflicting data. Confirm the exact model and stated specifications before committing.

Price to confirmProduct source
Klinwass Dolphin 15.3 kW

Klinwass Dolphin 15.3 kW

Pool heat pump · electrical supply: 220–240 V / 50 Hz · single-phase · refrigerant: R32. Published indicative pool volume: 30–60 m³. Guidance for a private in-ground pool with a bubble cover; not guaranteed year-round capacity.

Air 27 °C · Water 26 °C · Air wet bulb 24.3 °C · Outlet water 28 °C

Mode: Boost

Heating output: 15.3 kW

COP: 6.35

Boost mode at the stated conditions. Inlet water 26 °C and outlet 28 °C; air wet bulb 24.3 °C.

Selection requires a thermal assessment and checks of flow, electrical supply and the manual of the supplied unit. The public retail price is equipment only; delivery and additional work are confirmed separately. The listing and technical documents, or document revisions, contain conflicting data. Confirm the exact model and stated specifications before committing.

Price to confirmProduct source
Klinwass Dolphin 18 kW

Klinwass Dolphin 18 kW

Pool heat pump · electrical supply: 220–240 V / 50 Hz · single-phase · refrigerant: R32.

Air 27 °C · Water 26 °C · Air wet bulb 24.3 °C · Outlet water 28 °C

Mode: Boost

Heating output: 18 kW

COP: 6.36

Boost mode at the stated conditions. Inlet water 26 °C and outlet 28 °C; air wet bulb 24.3 °C.

Air 15 °C · Water 26 °C · Air wet bulb 12 °C

Mode: Boost

Heating output: 13.33 kW

COP: 4.95

Boost mode at the stated conditions. Inlet water temperature; air wet bulb 12 °C.

Selection requires a thermal assessment and checks of flow, electrical supply and the manual of the supplied unit. The public retail price is equipment only; delivery and additional work are confirmed separately. The listing and technical documents, or document revisions, contain conflicting data. Confirm the exact model and stated specifications before committing.

Price to confirmProduct source
Klinwass Dolphin 21.1 kW TINV

Klinwass Dolphin 21.1 kW TINV

Pool heat pump · electrical supply: 380–415 V / 50 Hz · three-phase · refrigerant: to confirm.

Air 27 °C · Water 26 °C · Air wet bulb 24.3 °C · Outlet water 28 °C

Mode: Boost

Heating output: 21.1 kW

COP: 5.88

Boost mode at the stated conditions. Inlet water 26 °C and outlet 28 °C; air wet bulb 24.3 °C.

Selection requires a thermal assessment and checks of flow, electrical supply and the manual of the supplied unit. The public retail price is equipment only; delivery and additional work are confirmed separately. The listing and technical documents, or document revisions, contain conflicting data. Confirm the exact model and stated specifications before committing.

Price to confirmProduct source
Klinwass Dolphin 25.3 kW

Klinwass Dolphin 25.3 kW

Pool heat pump · electrical supply: 220–240 V / 50 Hz · single-phase · refrigerant: to confirm.

Air 27 °C · Water 26 °C · Air wet bulb 24.3 °C · Outlet water 28 °C

Mode: Boost

Heating output: 25.3 kW

COP: 5.88

Boost mode at the stated conditions. Inlet water 26 °C and outlet 28 °C; air wet bulb 24.3 °C.

Air 15 °C · Water 26 °C · Air wet bulb 12 °C

Mode: Boost

Heating output: 17.1 kW

COP: 4.93

Boost mode at the stated conditions. Inlet water temperature; air wet bulb 12 °C.

Selection requires a thermal assessment and checks of flow, electrical supply and the manual of the supplied unit. The public retail price is equipment only; delivery and additional work are confirmed separately. The listing and technical documents, or document revisions, contain conflicting data. Confirm the exact model and stated specifications before committing.

Price to confirmProduct source
Klinwass Dolphin 28.1 kW TINV

Klinwass Dolphin 28.1 kW TINV

Pool heat pump · electrical supply: 380–415 V / 50 Hz · three-phase · refrigerant: to confirm.

Air 27 °C · Water 26 °C · Air wet bulb 24.3 °C · Outlet water 28 °C

Mode: Boost

Heating output: 28.1 kW

Boost mode at the stated conditions. Inlet water 26 °C and outlet 28 °C; air wet bulb 24.3 °C. COP is omitted at this condition because the datasheet rows disagree.

Air 15 °C · Water 26 °C · Air wet bulb 12 °C

Mode: Boost

Heating output: 18.5 kW

COP: 4.95

Boost mode at the stated conditions. Inlet water temperature; air wet bulb 12 °C.

Selection requires a thermal assessment and checks of flow, electrical supply and the manual of the supplied unit. The public retail price is equipment only; delivery and additional work are confirmed separately. The listing and technical documents, or document revisions, contain conflicting data. Confirm the exact model and stated specifications before committing.

Price to confirmProduct source
Klinwass Dolphin 25.3 kW TINV

Klinwass Dolphin 25.3 kW TINV

Pool heat pump · electrical supply: 380–415 V / 50 Hz · three-phase · refrigerant: to confirm.

Air 27 °C · Water 26 °C · Air wet bulb 24.3 °C · Outlet water 28 °C

Mode: Boost

Heating output: 25.3 kW

COP: 5.8

Boost mode at the stated conditions. Inlet water 26 °C and outlet 28 °C; air wet bulb 24.3 °C.

Air 15 °C · Water 26 °C · Air wet bulb 12 °C

Mode: Boost

Heating output: 16.7 kW

COP: 4.92

Boost mode at the stated conditions. Inlet water temperature; air wet bulb 12 °C.

Selection requires a thermal assessment and checks of flow, electrical supply and the manual of the supplied unit. The public retail price is equipment only; delivery and additional work are confirmed separately. The listing and technical documents, or document revisions, contain conflicting data. Confirm the exact model and stated specifications before committing.

Price to confirmProduct source
Klinwass Mini 5 kW

Klinwass Mini 5 kW

Pool heat pump · electrical supply: 220–240 V / 50 Hz · single-phase · refrigerant: to confirm. Published indicative pool volume: ≈ 25 m³. Private covered pool, May to September and ambient air at least 15 °C; the sheet states additional usage conditions.

Air 27 °C · Water 26 °C · Air wet bulb 24.3 °C · Outlet water 28 °C

Mode: Rated

Heating output: 5 kW

COP: 5.55

Nominal mode; separate from Boost. Inlet water 26 °C and outlet 28 °C; air wet bulb 24.3 °C.

Air 15 °C · Water 26 °C · Air wet bulb 12 °C

Mode: Rated

Heating output: 3.6 kW

COP: 4.3

Nominal mode; separate from Boost. Inlet water temperature; air wet bulb 12 °C.

Selection requires a thermal assessment and checks of flow, electrical supply and the manual of the supplied unit. The public retail price is equipment only; delivery and additional work are confirmed separately. The retailer mixes 15 and 20 m³; the Mini 5 kW sheet gives approximately 25 m³ under stated conditions. Ambient limits also conflict within the sheet.

Price to confirmProduct source
Klinwass Dolphin 7.2 kW

Klinwass Dolphin 7.2 kW

Pool heat pump · electrical supply: 220–240 V / 50 Hz · single-phase · refrigerant: R32.

Air 27 °C · Water 26 °C · Air wet bulb 24.3 °C · Outlet water 28 °C

Mode: Boost

Heating output: 7.2 kW

COP: 6.43

Boost mode at the stated conditions. Inlet water 26 °C and outlet 28 °C; air wet bulb 24.3 °C.

Air 15 °C · Water 26 °C · Air wet bulb 12 °C

Mode: Boost

Heating output: 5.4 kW

COP: 4.9

Boost mode at the stated conditions. Inlet water temperature; air wet bulb 12 °C.

Selection requires a thermal assessment and checks of flow, electrical supply and the manual of the supplied unit. The public retail price is equipment only; delivery and additional work are confirmed separately. The listing and technical documents, or document revisions, contain conflicting data. Confirm the exact model and stated specifications before committing.

Price to confirmProduct source
Klinwass Dolphin 9.5 kW

Klinwass Dolphin 9.5 kW

Pool heat pump · electrical supply: 220–240 V / 50 Hz · single-phase · refrigerant: R32.

Air 27 °C · Water 26 °C · Air wet bulb 24.3 °C · Outlet water 28 °C

Mode: Boost

Heating output: 9.5 kW

COP: 6.5

Boost mode at the stated conditions. Inlet water 26 °C and outlet 28 °C; air wet bulb 24.3 °C.

Air 15 °C · Water 26 °C · Air wet bulb 12 °C

Mode: Boost

Heating output: 7.9 kW

COP: 5.3

Boost mode at the stated conditions. Inlet water temperature; air wet bulb 12 °C.

Selection requires a thermal assessment and checks of flow, electrical supply and the manual of the supplied unit. The public retail price is equipment only; delivery and additional work are confirmed separately. The listing and technical documents, or document revisions, contain conflicting data. Confirm the exact model and stated specifications before committing.

Price to confirmProduct source
Klinwass Dolphin 11.5 kW

Klinwass Dolphin 11.5 kW

Pool heat pump · electrical supply: 220–240 V / 50 Hz · single-phase · refrigerant: R32.

Air 27 °C · Water 26 °C · Air wet bulb 24.3 °C · Outlet water 28 °C

Mode: Boost

Heating output: 11.5 kW

COP: 6.4

Boost mode at the stated conditions. Inlet water 26 °C and outlet 28 °C; air wet bulb 24.3 °C.

Air 15 °C · Water 26 °C · Air wet bulb 12 °C

Mode: Boost

Heating output: 8.23 kW

COP: 5.1

Boost mode at the stated conditions. Inlet water temperature; air wet bulb 12 °C.

Selection requires a thermal assessment and checks of flow, electrical supply and the manual of the supplied unit. The public retail price is equipment only; delivery and additional work are confirmed separately. The listing and technical documents, or document revisions, contain conflicting data. Confirm the exact model and stated specifications before committing.

Price to confirmProduct source
Midea MSC-70D2N8-A

Midea MSC-70D2N8-A

Pool heat pump · electrical supply: 220–240 V / 50 Hz · single-phase · refrigerant: R32. Published indicative pool volume: < 35 m³ · A15/W28. Published indicative volume does not specify cover, wind or operating schedule; it does not guarantee performance.

Air 27 °C · Water 28 °C · Humidity 80%

Mode: Nominal

Heating output: 7.16 kW

COP: 7.5

Nominal mode; separate from Boost.

Air 27 °C · Water 28 °C · Humidity 80%

Mode: Boost

Heating output: 10.3 kW

COP: 6.6

Boost mode at the stated conditions.

Air 15 °C · Water 28 °C · Humidity 70%

Mode: Nominal

Heating output: 5.3 kW

COP: 5.1

Nominal mode; separate from Boost.

Air 15 °C · Water 28 °C · Humidity 70%

Mode: Boost

Heating output: 7.3 kW

COP: 4.69

Boost mode at the stated conditions.

Selection requires a thermal assessment and checks of flow, electrical supply and the manual of the supplied unit. The public retail price is equipment only; delivery and additional work are confirmed separately. Water limits differ between Midea sheet revisions. Confirm them in the supplied manual; operation at −7 °C does not establish available heating output at that temperature.

Price to confirmProduct source
Midea MSC-120D2N8-A

Midea MSC-120D2N8-A

Pool heat pump · electrical supply: 220–240 V / 50 Hz · single-phase · refrigerant: R32. Published indicative pool volume: < 60 m³ · A15/W28. Published indicative volume does not specify cover, wind or operating schedule; it does not guarantee performance.

Air 27 °C · Water 28 °C · Humidity 80%

Mode: Nominal

Heating output: 12.5 kW

COP: 7

Nominal mode; separate from Boost.

Air 27 °C · Water 28 °C · Humidity 80%

Mode: Boost

Heating output: 14.5 kW

COP: 6.35

Boost mode at the stated conditions.

Air 15 °C · Water 28 °C · Humidity 70%

Mode: Nominal

Heating output: 9.12 kW

COP: 5.05

Nominal mode; separate from Boost.

Air 15 °C · Water 28 °C · Humidity 70%

Mode: Boost

Heating output: 10.5 kW

COP: 4.6

Boost mode at the stated conditions.

Selection requires a thermal assessment and checks of flow, electrical supply and the manual of the supplied unit. The public retail price is equipment only; delivery and additional work are confirmed separately. Water limits differ between Midea sheet revisions. Confirm them in the supplied manual; operation at −7 °C does not establish available heating output at that temperature.

Price to confirmProduct source

Technical data and sources checked 05 October 2026.

Pool heating questions

Is pool volume enough to choose a heat pump?

No. Volume helps estimate the energy for the initial warm-up. Selecting output also requires water surface area, outdoor temperature, wind, cover and the intended swimming season.

What should an installation quote include?

It should list the heat pump, bypass, pipes, valves, electrical supply, protection, base and commissioning. Route lengths, access and changes to filtration can affect the cost. We confirm the scope for each pool.

Is heating energy the same as electricity consumption?

No. The initial calculation describes heat needed in the water. Electricity use depends on the actual COP and heat losses during warm-up and temperature maintenance. A cover helps reduce losses, particularly evaporation.

What we check before installation

  • Water volume and surface area, depth, indoor or outdoor pool
  • Season, target temperature, cover and wind exposure
  • Filtration flow, bypass and water-treatment compatibility
  • Airflow, clearances, noise and condensate drainage
  • Supply phases, available electrical capacity, connections and protection
  • Commissioning, settings, winterising and maintenance

What makes up the quote

Heat pump, fittings and bypass, hydraulic route, electrical supply, base, installation and commissioning. The pool cover is considered separately. The questionnaire keeps the inputs and outstanding checks; final output and installed price follow a thermal assessment.

Pool water treatment

Filtration, disinfection and pH control are a separate task. We coordinate heating with the existing treatment system.

View pool water treatment
Find my pool heating

For Catalonia, materials and pricing are confirmed through a regional proposal. Prices from other regions are not applied.

One home. One engineering team.

Let’s start with your home.

WhatsApp